Stairmaster 4400 PT/CL Fitness Equipment User Manual


 
Page 67
UPPER HANDLES (4600 PT/CL)
1. Disconnect the left and right contact heart rate cables from the back
of the console.
2. Remove the two mounting screws from the top and bottom shield
and remove the shields from the upper handle assembly.
3. Remove the four handrail adapter screws from the upper handle
assembly.
4. Remove the upper handle assembly from the machine. The contact
heart rate cables are threaded through the handrail adapter. Remove
the handrail adapter from the contact heart rate cables.
5. Reverse the removal procedures to install the new upper handle
assembly.
SIDE HANDRAILS (4600 PT/CL)
1. Disconnect the left and right
contact heart rate cables
from the back of the console.
2. Remove the two mounting
screws from the top and bottom
shield (see Figure 20) and remove
the shields from the upper handle
assembly.
3. Remove the four handrail
adapter screws from the upper
handle assembly.
4. Remove the upper handle assembly
from themachine. The contact heart rate
cables are threaded through the handrail
adapter. Remove the handrail adapter from the
contact heart rate cables. Set the upper handle assembly aside.
PARTS REMOVAL AND REPLACEMENT