31
Most INCLINE TRAINER problems can be solved by following the steps outlined in this section. Find any
symptoms that apply, and follow the steps listed. If further assistance is needed, please contact your dis-
tributor.
1. SYMPTOM: THE POWER DOES NOT TURN ON
a. Make sure that the power cord is plugged into a properly grounded outlet. (See page 10.)
b. Make sure that the key is inserted into the console.
c. Check the on/off circuit breaker located on the INCLINE TRAINER near the
power cord. Make sure that the on/off circuit breaker is switched to the on
position.
2. SYMPTOM: THE POWER TURNS OFF DURING USE
a. Check the on/off circuit breaker located on the INCLINE TRAINER near the power cord. (See drawing 1. c.
above.) Make sure that the on/off circuit breaker is switched to the on position.
b. Make sure that the power cord is plugged in.
c. Remove the key from the console. Reinsert the key into the console.
d. Check the walking belt and the walking platform for excessive wear. Replace the walking belt or the walking
platform if necessary.
e. If the power still turns off during use, please contact your distributor.
3. SYMPTOM: THE WALKING BELT SLOWS WHEN WALKED ON
a. If the walking belt is overtightened, performance may
decrease and the walking belt may be damaged. If
the walking belt is properly tightened, you should be
able to lift each side of the walking belt 2.5 to 5 cm (1
to 2 in.) off the walking platform. If adjustments
need to be made, first remove the key and unplug
the power cord. Using the included hex key, turn
both roller adjustment bolts counterclockwise 1/4 of a
turn. Be careful to keep the walking belt centred. Plug
in the power cord, insert the key, and use the IN-
CLINE TRAINER for a few minutes. Repeat until the
walking belt is properly tightened. Note: To tighten
the walking belt, see step 7. c. on page 32.
b.
Make sure that the walking platform is properly lubricated. (See step 4 of MONTHLY
MAINTENANCE on
page 27.)
c. If the walking belt still slows when walked on, please contact your distributor.
“On”
Position
c
1.52 m
a
2.5–5 cm
TROUBLESHOOTING
Roller Adjustment Bolts