11 - 3
Test Menu
When you scan the Test Menu On code, then scan a programming code in this
manual, the imager displays the content of a programming code. The program-
ming function will still occur, but in addition, the content of that programming
code is output to the terminal.
Note: This feature should not be used during normal imager operation.
2D PQA (Print Quality Assessment)
Two-dimensional Print Quality Assessment (2D PQA) is a feature of Honeywell’
image readers where the data from the successful read of a 2D bar code sym-
bol is augmented with lines of text that both identify the symbol, and also report
graded measurement parameters obtained from it.
2D PQA Reporting
Honeywell' 2D PQA reporting can be enabled in two different modes: Full
Report or Screening. (To see displayed results, Microsoft® Notepad, a word
processor/editing program, or Quick*View (page 11-6) is recommended.)
If you are using Quick*View, you can enable Full Report, a listing of all of a sym-
bol's identifying information, measurements, and corresponding grades, by typ-
ing the following menu command:
2D_PQA1
or by scanning the following bar code:
Note: The PQA report is sent out as a second data/beep sequence after the bar
code data. The report has its own Honeywell code ID of >(0X3E) so it can
be uniquely identified.
On
* Off
Full Report