PROBLEM:Thetreadmill circuit breakertrips during a workout.
$SLUTJON: Verifythe following:
• Make sure the treadmill is plugged into a dedicated 20-amp circuit.
• Verifythat you do not ha vethe machine on an extensioncordor surge protector
• Confirm that the machine is not plugged into a GFCI-equippefi outlet or on a circuit that has a GFCI-equippefloutlet on it.
PROBLEM:The running belt does not stay centered during a workout.
$OLUT]OHi Verifythe following:
• Make sure the treadmill is on a level surface.
• Verifythat the belt is properly tightened and centered(Refer to the Adjustment section for detailed directions).
54
PROBLEM:Operating speed appears inaccurate.
$OL UT]OH: Auto-cafibrate the treadmill:
• Poweron the treadmill and have the safety keyin position on the
console.Press and hold the elevation "+" and speed %" buttons for
approximately 5 seconds toenter the Engineering Mode. Theconsole
will beepand "ENGO"appears in the display.
• Press the Speed "+" or "-" button until "ENG2"appears in the display.
• Press, "ENTER"to select. Press, "START"to begin. Thetreadmill
running belt will begin to move automatically and the auto-calibration
sequence will properly set and store the speed values.
• Uponsuccessful calibration, the treadmill will beepseveral times. The
console will automatically exit Engineering Modeand return to the
start-up screen.
i DONOTstandonrunningbe!twhile
i ca!ibrating-stand onthe guide
rails. Treadmillwill fluctuate between
i low and high SPeedsfoi severai
_minutes until calibration is completel
TROUBLESHOOTING- HEARTRATE
Checkyour exerciseenvironment for sourcesof interference such as fluorescent lights, computers, undergroundfencing, home
security systems or appliances containing large motors. Theseitems may cause erratic heart rate readouts.
Youmay experiencean erratic readout under the following conditions:
° Gripping the heart rate handlebars too tighL Tryto maintain moderatepressure while holding onto the heart rate handlebars.
• Constantmovement and vibration due to constantly holding the heart rate handlebars while exercising.If you arereceiving
erratic heart rate readouts, try to only hold the grips long enough to monitor your heart rate.
• Whenyou are breathing heavily during a workout.
• Whenyour hands are constricted by wearing a ring.
• Whenyour hands are dry or cold. Tryto moisten your palms byrubbing them together to warm.
• Anyonewith heavyarrhythmia.
° Anyonewith arteriosclerosis orperipheral circulation disorder
• Anyonewhoseskin on the measuring palm is especially thick.
Thefollowinginformationmaybeaskedofyou whenyoucall.Pleasehavetheseitemsreadilyavailable:
• ModelName
• SerialNumber
• Dateof Purchase(receiptorcreditcardstatement)
In orderfor CustomerTechSupporttoserviceyourtreadmilltheymayneedto askdetailedquestionsaboutthesymptomsthatare
occurring.Sometroubleshootingquestionsthatmaybeaskedare:
• Howlonghasthisproblembeenoccurring?
• Doesthisproblemoccurwitheveryuse?Witheveryuser?
• Ifyouarehearinga noise,doesit comefromthefrontor theback?Whatkind of noiseisit (thumping.grinding,squeaking,
chirpingetc.)?
• Hasthemachinebeenlubricatedandmaintainedperthemaintenanceschedule?
Answeringtheseandotherquestionswillgivethe technicianstheabilityto sendproperreplacementpartsandtheservicenecessary
togetyouandyourHorizonFitnesstreadmillrunningagain]