Cybex International LT-14464-4 Rev H Treadmill User Manual


 
10. Secure the front panel.
A. Avoid touching R34 and the black capacitors. Connect the motor cable. See Figure 1.
B. Using a 3/16” Allen wrench, secure the front panel to the frame with the four button
head screws and four starwashers.
11. Secure the motor cover.
A. Lower the motor cover in position and install the two Phillips head screws that hold it
in place.
12. Turn the power on.
A. Connect the treadmill to the power outlet.
B. Turn the main power switch to the on (I) position.
C. The treadmill will lower itself. Wait until the treadmill resets its elevation to 0%.
13. Clear the error log.
A. Enter Diagnostic Test Mode, press and hold SHIFT, then press -.
B. Display the error codes by pressing START (forward), SHIFT (backward) and scrolling
to Test 11. View each error code by pressing - +. Make a note of the errors and refer
to the manual for the interpretation of these errors.
C. To clear the entire error log press v
^
to exit Test 11, then press START to scroll to Test
12. Then press v
^
to cycle the display from ErrS (Error codes SET) to ErrC (Error
codes CLEARED). With ErrC displayed press START.
D. Exit Diagnostic Test Mode by pressing STOP.
Motor Current & Voltage
! WARNING: This motor current and voltage procedure should be performed by a
qualified service technician.
Check the Current Draw
Cybex recommends that a qualified technician check your motor current draw and measure
motor voltage as scheduled in the Service Schedule in the Preventive Maintenance chapter.
By performing these procedures you can evaluate the performance of your drive motor and
help prevent premature failure.
Cybex commercial treadmills have the unique feature of monitoring motor current from the
display board. The current measure is most accurate when used at 3.0 mph (4.8 km/h). With a
160 lb. (72.5 kg) person walking on the treadmill at this speed, the current measure number
Cybex 710T Treadmill Owner’s Manual
Page 7-4