Stairmaster 4200 PT Fitness Equipment User Manual


 
Page 64
PEDAL
1. Remove the snap ring and flat washer from the leveling arm pin and
the pedal shaft (see Figure 17).
2. Slide the pedal off the shaft.
3. Clean the pedal shaft and leveling arm pin with a dry cloth. Lubricate
the pedal shaft and the leveling arm pin with a thin coat of multi-
purpose grease.
4. Reverse the procedures to reinstall the pedal.
LEVELING ARM
1. Remove the pedal.
2. Remove the bottom cover.
3. Remove the snap ring that secures the leveling arm to the leveling
arm shaft (see Figure 19).
4. Slide or gently tap the leveling arm off the shaft.
5. Clean the shaft and the pin with a cloth dampened with 30W motor
oil before reassembly.
6. Reverse the removal instructions to reinstall the leveling arm.
PARTS REMOVAL AND REPLACEMENT
TO REDUCE THE RISK OF EYE INJURY, WEAR EYE
PROTECTION WHEN REMOVING SNAP RINGS.
!
WARNING
TO REDUCE THE RISK OF EYE INJURY, WEAR EYE
PROTECTION WHEN REMOVING SNAP RINGS.
!
WARNING