Stairmaster 4200 PT Fitness Equipment User Manual


 
Page 45
5. Follow the white power connector wire to the where it plugs into the
main cable white wire, and disconnect it from the main cable
white wire.
6. Set your voltmeter to VDC. Connect the positive lead of your
voltmeter to the white wire from the power connector and touch the
gray casing of the alternator with the negative lead of your voltmeter.
7. DC voltage measured should be 12 to 19 VDC. Replace the power
connector if the voltage is not the same value as in step 3. Connect
the two white wires.
8. Remove the console knobs from the back of the console, lift the
console up, and disconnect the 20-pin main cable from the console.
9. Test for 12 to 19 VDC in pins #1 (-) and #10 (+) in the main cable
connector. Replace the main cable if the voltage reading is not
the same as in step 7.
10. If all voltage readings have been within the specified range and the
console will not power up, the console should be replaced.
Alternator Test
11. Check for loose wiring connections on the alternator, diode, and load
resistor (see Final Assembly Figure).
12. Perform the Positive Output to Field test on the alternator:
Disconnect the power cord from the electrical outlet.
Remove the black wire from the B+ terminal on the alternator.
Remove the brown wire from the field terminal on the alternator.
ELECTRICAL TROUBLESHOOTING