COMMERCIAL PRODUCTS DIVISION
Press Enter once again and the Error Log appears. Press the or key to view
the error messages. To return to the Precor banner, press Enter or Reset.
Note: To clear (delete) the error log, press Quick Start for at least 4 seconds
while viewing the list. Prompts appear on the display and let you know when the
error messages have been deleted (“cleared” from memory).
Important: You cannot retrieve the error log once you have deleted it.
USING CSAFE STANDARD EQUIPMENT
The EFX546 is fully compatible with CSAFE protocols. If the unit is connected
to a CSAFE master device, the user will be prompted to enter a user ID. Five
zeros appear on the display. The left zero blinks to indicate that it is awaiting
input. The following table provides information about the keypad functions:
User ID Entry: Program Keys
or moves the blinking LED from field to field.
Number keypad use the number keys to enter a user ID. The number that is
pressed appears in the display and the next field begins to
blink. When all 5 user ID numbers are selected, the user
must press Enter to submit it.
Enter submits the displayed user ID. Note that if the 5 zeros are
being displayed when the user presses Enter, the user ID
entry is bypassed and the Course prompt appears.
Reset resets the display to the Precor banner.
A message indicates when the user ID is accepted by the CSAFE master de-
vice. Then, the Course prompt is displayed. See
Quick Steps to Working Out