IBM S84H-4552-00 Bicycle Accessories User Manual


 
Numeric Error Codes
Symptom or Error FRUs of the SelectaDock
Sequence of Actions
10X, 11X
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt
failure.
104: Protected mode
failure.
105: Last 8042
command not
accepted.
107: NMI test failure.
108: Timer bus test
failure.
109: Low meg-chip
select test.
1. Adapter in slot (if
used)
2. Riser card
3. Main card
195
(The computer was docked
to the SelectaDock Docking
System while in hibernation
mode.)
1. Do the following
steps.
a. Power-off and
undock the
system.
b. Power-on and
shut down the
system.
c. Power-off and
dock the system.
1XX 1. See the Hardware
Maintenance Manual
of the computer. If
the problem remains,
go to “Undetermined
Problems” on
page 30.
2XX
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
1. See the Hardware
Maintenance Manual
of the computer.
2. Main card
3XX 1. See “External
Keyboard” on
page 11.
19