Newcon Optik NC 3-12X50 Hunting Equipment User Manual


 
14
TABLE 3
A B C D E F G H
Size in
cm
@100m
distance
100
7.5
0.5
4.0
10
1.5
5
2
The segments of the reticle for other magnification
settings are given in the Table 4 (all numbers are
measured in cm @100m).
TABLE 4
Magnification, x A B C D E
3
400 28.0 2.0 10.0 40.0
4
300 21.0 1.5 7.50 30.0
6
200 14.0 1.00 5.00 20.0
8
150 10.5 0.75 3.8 15.0
10
120 8.4 0.60 3.0 12.0
12
100 7.0 0.50 2.5 10.0
It’s possible to determine segments size for any
magnification with the formula:
[specified size at 12x] х 12
Size of the segment at 100 m = --------------------------------
(with magnification V) Selected magnification V