Life Fitness 93T Treadmill User Manual


 
10
1.2 SETUP
Read the Operation Manual before setting up the Life Fitness treadmill. Place the treadmill
where it will be used before beginning the setup procedure.
ELECTRICAL POWER REQUIREMENTS
The Life Fitness Treadmill requires a dedicated*
line according to the electrical configurations
listed in the chart below.
* One individual branch circuit for each treadmill per NEC
article 210-21 (b) (1) and 210-23 (or other appropriate,
country specific electrical compliance guidelines). The hot,
neutral and ground wires must each be routed independent-
ly (not looped or tied to other circuits.)."
NOTE: Do not modify the plug provided with this product. If the plug does not fit into an available
electrical outlet, have a proper outlet installed by a qualified electrician.
GROUNDING INSTRUCTIONS
This Life Fitness product must be properly grounded. If the unit malfunctions or breaks down,
proper grounding provides a path of least resistance for the electric current, which reduces the
risk of shock to anyone touching or using the equipment. Each unit is equipped with an electrical
cord, which includes an equipment grounding conductor and a grounding plug. The plug must
be inserted into an outlet that has been properly installed and grounded in accordance with all
local codes and ordinances.
A temporary adapter MUST NOT BE USED to connect this plug to a 2-pole receptacle
in North America. If a properly grounded, 20 AMP outlet is not available, one must be
installed by a qualified electrician. Models drawing 20-amps must be installed on a
dedicated line.
IL EST ABSOLUMENT INTERDIT d'employer un adaptateur temporaire pour brancher cette
fiche sur une prise bipolaire en Amérique du Nord. Si aucune prise de 20 A correctement
mise à la terre n'est disponible, en faire installer une par un électricien qualifié. Les mod-
èles utilisant 16 A ou plus doivent être branchés sur un circuit spécialisé.
DANGER: A risk of electrical shock may result from improper connection of
the equipment-grounding conductor. Check with a qualified electrician if in doubt as
to proper grounding technique. DO NOT modify the plug provided with the product. If
it will not fit an electrical outlet, have a proper outlet installed by a qualified electri-
cian. Any modification to the electrical plug will result in a voided warranty.
Un branchement incorrect du conducteur de mise à la terre peut entraîner des risques de
décharge électrique. Consulter un électricien si des doutes subsistent quant à la technique de
mise à la terre. NE PAS MODIFIER la fiche fournie avec l'appareil. Si elle ne s'adapte pas à une
prise, faire installer une prise correcte par un électricien qualifié. Toute modification à la fiche
annule la garantie.