Cissell CAB438C Home Gym User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Maintenance
AJ0975
24
Periodic Inspections
Table 3
Timer Intervals Operation or Inspection Corrective Action
Daily or as required Visually inspect the air intake filters. Replace when dirty. They are
throwaway-type filters but can be
cleaned once before discarding.
Visually inspect intake air screen. Remove lint from screen.
NOTE: Do not operate blowers unless air filters are installed.
Visually inspect the sight glass in the air
line filter at the inlet.
If moisture and oil are collecting in the
bowl, the auto-drain is not working.
Clean, repair or replace air filter.
Visually check the discharge tube gasket. Replace worn or missing gasket.
NOTE: DO NOT operate press if discharge tube gasket is missing.
Weekly Inspect air line filter for sediment. Clean as necessary.
Inspect all safety labels. See Parts
Manual for location and description of
labels.
Replace labels which are damaged,
missing or unreadable.
Inspect buck stop adjustments. Shock
absorber should not bottom out.
Adjust shock or bumper as required.
Every 2 weeks Inspect steam strainers in steam inlet and
outlet lines and in traps.
Clean strainers and traps.
Inspect each blower motor intake for lint
build-up.
Remove lint from motor.
Inspect customer-furnished steam traps
per instructions provided with traps.
Clean as necessary.
Monthly Check all steam and air connections for
visual signs of leakage.
Tighten any loose connections. Replace
lines where necessary.
Check condition of the flexible steam
hoses.
Steam hoses with broken braids must be
replaced.
Attempt to rock buck at operator station
back and forth; check rollers against
rails.
If buck carriage rollers are loose against
rails, tighten as required. Rollers should
be snug, but not too tight.
Every 6 months Remove all covers and check cap
screws, fittings and cylinders for security
of attachments.
Tighten as required.