Cateye CC-TR100 Cyclometer User Manual


 
CC-TR100
1312
CC-TR100
MODE-
1
or
MODE-
2
M
K
S/S/E
5. Tire circumference input
Enter the circumference of the tire of your bicycle in mm. 2096 mm (700 x 23 C) is preset as
the initial value. To change the value, use the MODE-2 button to increase the value, and use the
MODE-1 button to shift the digit selected.
Pressing the START/STOP/ENTER button and this is the last step in the initial set-up.
Adjustable range: 0100 to 3999 mm
NOTE: You can find your approximate tire size on the tire circumference chart on page 53.
When a value outside the adjustable range is entered, an error indication appears on
the screen and you cannot select the value.
MODE-
1
MODE-
1
MODE-
2
S/S/E
6. Operation test
Test the functioning of the speed sensor, cadence sensor, and remote buttons with the main
unit attached to the receiver.
1. Raise the rear wheel and spin the tire, and make sure that the speed (Display 1) shows a
number greater than zero.
2. Turn the crank (backpedal) and make sure that the cadence (Display 3) shows a number
greater than zero.
OK
OK
NOTE: If the screen remains at 0, the relative positions of the magnets to the sensors
may be inappropriate. Follow the instructions given in Installing the unit on your
bicycle, on page 8.
3. Press the right and left remote buttons to check that you can operate the main unit with
them.
NOTE: If the button is not operable, it indicates that the main unit and/or the button
connector may not have been installed properly.
In the initial setup, the MODE-1 and MODE-2 button functions have been speci-
fied. To change the settings, see Defining remote button setting on page 33.
Completion of initial set-up
When the setup is completed, set the date and time as described in Configuring main unit
on page 28.
Display-1Rotate the rear wheel Display-3Rotate the crank arm
Changing a value
Select
Increases the value
Shifting the digit
3. Checking heart rate sensor ID
The heart rate sensor ID must be checked within five minutes after the formatting or restarting
operation.
Before performing an ID check, mount the main unit to the HR receiver.
NOTE: Be sure to attach the main unit to the HR receiver. Signals from the heart rate sensor
cannot be received by the main unit alone.
Place the heart rate sensor approximately 20-80 cm from the main unit, and press the reset
button of the HR sensor for five seconds. The main unit will receive the signal from the heart
rate sensor, and will start checking the heart rate sensor ID. When the check is completed, the
ID number is displayed, followed by the next screen.
NOTE: If the HR sensor is placed too close to the main unit (within 20 cm), the main unit
cannot receive the ID signal. If an ID check failed, change the distance, and reset the
heart rate sensor.
If E appears on Display-2, or a HR sensor ID check failed even at a proper distance,
the batteries may be dead. Replace the batteries of the heart rate sensor in the proce-
dure shown on page 48, and format (restart) the computer again.
Pressing the reset
button for five seconds
Select
Switch
For formatting
4. Selecting speed
unit
For restarting
Ready
4. Selecting speed unit
The default speed unit is km/h.
By pressing the MODE-1 or MODE-2 button, you can switch the unit between K (km/h) and
M (miles/h). Select the desired speed unit, and press the START/STOP/ENTER button. The
selected unit is now accepted, and the tire circumference screen appears.
Attach the main unit to
the receiver.