Newcon Optik LRF MOD 4EC Hunting Equipment User Manual


 
21
Data Recall mode
In the Data Recall mode results of the last 10 measurements can
be displayed.
Measurement results are saved in on-board memory in sets
depending on the parameters set for measuring, for instance, if
only distance is measured - the set will consist of one number, if
distance and azimuth are measured – the set will consist of two
numbers.
To enter the Data Recall mode press the M button in the Ready
to Measure mode until
rEc is displayed and then press the A
button. First measurement set number (display name:
rEc 1)
will start flashing.
Pressing the M button moves the unit along the list of
measurement set numbers and measurement results:
rEc 1, distance 1, azimuth 1, elevation 1,
rEc 2, distance 2, azimuth 2, elevation 1, …,
rEc 0, distance 0, azimuth 0, elevation 0.
Measurement sets are numbered in reverse order: first recalled
set is the result of the last measurement. If any parameter has not
been actually measured it will not be recalled.
Pressing the A button at any moment within the list of recalled
results (or pressing the M button at the end of the list) brings the
unit to the Ready to Measure mode.
Choosing
cLr in the Setup mode will erase all measurement
data.