ADTRAN 1204002L2 Heart Rate Monitor User Manual


 
Chapter 3. Operation
61200275L1-1 TSU IQ+ User Manual 3-5
VT-100 Terminal Connection and Operation
To control the TSU IQ+ using a VT-100 terminal, follow this
procedure:
1. Using the front panel interface, set the TSU IQ+ baud rate to
match the terminal. Select 1C
ONFIG
; then select C
ONTROL
P
ORT
.
2. Using the ADTRAN-provided VT-100 terminal adapter,
connect the
COM
port of a VT-100 compatible terminal or
equivalent to the eight-pin modular jack labeled
CONTROL
on
the rear of the TSU IQ+. This connection is used for both local
and remote configuration.
3. Open the connection and press
Enter
repeatedly until the
L
OGIN
Menu appears (Figure 3-3 on page 3-6).
4. Select L
OCAL
L
OGIN
to configure the TSU IQ+ unit connected to
the terminal.
5. Select R
EMOTE
L
OGIN
to configure a remotely located TSU IQ+
unit.
6. For remote applications, at the remote DLCI prompt, enter the
outgoing DLCI (see the following note) by pressing
1
,then
Enter
, entering the DLCI number, and pressing
Enter
again.
7. Select B
EGIN
R
EMOTE
S
ESSION
by pressing
2
and
Enter
.
8. Enter the password. The factory default password is
adtran
.
The M
AIN
menu will appear (Figure 3-4 on page 3-6).
9. Make selections by entering the number corresponding to the
chosen parameter. Press
ESC
to return to the previous screen.
When entering the DLCI for a remote application, enter the DLCI associ-
ated with the local unit that you are logged into (not the far end DLCI).
If the wrong DLCI is entered or a network problem exists, the screen freez-
es at the P
RESS ANY KEY TO CONTINUE
prompt. Press
CNTL
+
L
twice
to return the unit to the L
OGIN
screen.