5.1 Measurement Section
The measurement resistance range is automatically selected from the following
according to the actual measured value. The resistance range cannot be set
manually.
Measurement Resistance Range (0 to 200.0 M)
2-M Range Max. display value: 2.000 M (0.001 - M resolution)
20-M
Range
Max. display value: 20.00 M (0.01 - M resolution)
200-M Range Max. display value: 200.0 M (0.1 - M resolution)
Testing Thresholds
Shoes Test Lower Threshold resistance: 100 k or 1 M
Upper Threshold resistance: 10, 35 or 100 M
Wrist Strap Test
Lower Threshold resistance: 0.65 M
Upper Threshold resistance: 15, 10 or 35 M
rdg. (displayed or indicated value)
This signifies the value actually being measured, i.e., the value that is currently indicated or
displayed by the measuring instrument.
dgt. (resolution)
Signifies the smallest display unit on a digital measuring instrument, i.e., the value displayed
when the last digit on the digital display is “1.”