16 R_BLK_DC 80/80/80 0 ~ 255 AV Pedestal Adjustment video/1080i,1035i,720p/480p,525p
17 VRB 115 0 ~ 255 dac3 A/D Ref Voltage Adjustment {BOTTOM]
18 GVRT 130 0 ~ 255 dac2 A/D Ref Voltage Adjustment [TOP]
19 BVRT 130 0 ~ 255 dac2
20 RVRT 130 0 ~ 255 dac2
21 R_V_COM_CEILING 0 0 ~ 255 dac2 R-common center adjustment, deferential value at Ceiling On (0:±0, 1:+1, 255:-1)
22 G_V_COM_CEILING 0 0 ~ 255 dac2 G-common center adjustment, deferential value at Ceiling On (0:±0, 1:+1, 255:-1)
23 B_V_COM_CEILING 0 0 ~ 255 dac2 B-common center adjustment, deferential value at Ceiling On (0:±0, 1:+1, 255:-1)
24 NRSB_CEILING 0 0 ~ 255 NRSB , deferential value at Ceiling On (0:±0, 1:+1, 255:-1)
25 NRSA_CEILING 0 0 ~ 255 NRSA , deferential value at Ceiling On (0:±0, 1:+1, 255:-1)
Group:6 TC90A69F
0Y-EQ_GAIN 3 0 ~ 3
1Y-EQ_N_C_LIM 3 0 ~ 3
2V-ENH_GAIN 4 0 ~ 7
3 V_ENH_CORING 2 0 ~ 3
4 NTSC443_SW 1 0 ~ 1 Set for input signal system 0:NTSC4.431:PAL60 (It is effective when input signal is NTSC4.43)
Group:10 Option
0 Lamp Time Monitor - 0~8738 Read only
1 RS232C Baudrate 0 0 ~ 1 0:19200bps1:9600bps
2 Shootout Mode 0 0 ~ 1 1:Shoot Out Mode Enable0:Disable
3 Cooling Time 3 0 ~ 15 Cooling time setting 1:30 sec.3:90 sec.15:450 sec.0:continuously On
4Hi-Land SW 0 0 ~ 255 0:Land mode(Normal operation) 1:High-land mode(Fan spinning in max speed)
5V-Douki SW 0 0 ~ 1 0:V synchronized1:V not synchronized
6 Lamp Total Time - 0~65535 Read only
7 Net Board Reset 1 0 ~ 1 0:Reset unable, 1: Reset enable
8Keystone Option 0 0 ~ 1 0:Fixed limitation 1:Change limitation according to input signal
9 Syukka SW 0 0 ~ 10 Reset user control value when the data changes to 10 and turns to 0.
10 Color Shading SW 1 0 ~ 1 0:On 1:Off
11 RC Enable/Disable 0 0 ~ 3 0:Activate both Front and Rear RC 1:Prohibition-Front 2:Prohibition-Front 3:Deactivate both Front and Rear RC
12 Lamp Dim Level 0 0 ~ 10 0:Maximum (250W)10:Minimum(200W)
13 Lamp Warning Time 1000 0~65535 in hours, can not be changed
14 Forced NOBRAND 0 0 ~ 1 0:Normal 1:On
15 Forced Video Mute Off 0 0 ~ 1 0:VideoMuteOn(Normal) 1:Forced VideoMuteOff
16 Fan Control SW for Testing 0 0 ~ 4 0:Normal, 1: Normal Min., 2:NormalMax., 3:Eco Min., 4:Eco Max.but not be memorized
Group:11 Fan Control
0FAN_TEMP_A_WARNING 39 30 ~ 100 Temperature A to judge the abnormal (Not memorized) Room
1FAN_TEMP_B_WARNING 50 30 ~ 100 Temperature B to judge the abnormal (Not memorized) Panel
2FAN_TEMP_C_WARNING 67 30 ~ 100 Temperature C to judge the abnormal (Not memorized)lamp
3FAN_TEMP_B-A_WARNING 25 0 ~ 100 Temperature B-A to judge the abnormal (Not memorized) Detection of filter croggle
4FAN_TEMP_C-A_WARNING 43 0 ~ 100 Temperature C-A to judge the abnormal (Not memorized) Detection of filter croggle
5FAN_CONTROL_SW 0 0 or 1 0:Fan Control automatically 1:Fan Control Manually FAN Voltage Adjustment
6FAN_A_SPEED - 0 ~ 255 Only effective when FAN_CONTROL_SW = 1
7FAN_B_SPEED - 0 ~ 255 Initial Normal/Eco
8FAN_C_SPEED - 0 ~ 255
9FAN_TEMP_A_MONI - - Read only
10 FAN_TEMP_B_MONI - -
11 FAN_TEMP_C_MONI - -
12 FAN_ANZEN_MINMAX 1 0 or 1 Only effective when FAN_CONTROL_SW=1, it can be used with10-12 but not be memorized.
13 TEMP_NOWARNING_TIME 3 0 ~ 5 Do not detect temp error within specified time after turn on.
14 NOR_TEMP_FAN1_MIN 28 FAN1 temperature to start the control, Normal
15 NOR_TEMP_FAN1_MAX 36 FAN1 temperature to end the control, Normal
16 NOR_TEMP_FAN2_MIN 28 0~255 FAN2 temperature to start the control, Normal
17 NOR_TEMP_FAN2_MAX 36 FAN2 temperature to end the control, Normal
18 NOR_TEMP_FAN3_MIN 28 FAN3 temperature to start the control, Normal
19 NOR_TEMP_FAN3_MAX 36 FAN3 temperature to end the control, Normal
20 NOR_VALU_FAN1_MIN 90 FAN1 control minimum value, Normal( 0:Fan voltage 0V, 255:Fan voltage 25.5V)
21 NOR_VALU_FAN1_MAX 135 FAN1 control maximum value, Normal
22 NOR_VALU_FAN2_MIN 80 0~255 FAN2 control minimum value, Normal
23 NOR_VALU_FAN2_MAX 135 FAN2 control maximum value, Normal
24 NOR_VALU_FAN3_MIN 70 FAN3 control minimum value, Normal
25 NOR_VALU_FAN3_MAX 105 FAN3 control maximum value, Normal
26 ECO_TEMP_FAN1_MIN 28 FAN1 temperature to start the control, Eco
27 ECO_TEMP_FAN1_MAX 36 FAN1 temperature to end the control, Eco
28 ECOTEMP_FAN2_MIN 28 0~255 FAN2 temperature to start the control, Eco
29 ECO_TEMP_FAN2_MAX 36 FAN2 temperature to end the control, Eco
30 ECO_TEMP_FAN3_MIN 28 FAN3 temperature to start the control, Eco
31 ECO_TEMP_FAN3_MAX 36 FAN3 temperature to end the control, Eco
32 ECO_VALU_FAN1_MIN 55 FAN1 control minimum value, Eco
33 ECO_VALU_FAN1_MAX 120 FAN1 control maximum value, Eco
34 ECO_VALU_FAN2_MIN 70 0~255 FAN2 control minimum value, Eco
35 ECO_VALU_FAN2_MAX 100 FAN2 control maximum value, Eco
36 ECO_VALU_FAN3_MIN 55 FAN3 control minimum value, Eco
37 ECO_VALU_FAN3_MAX 75 FAN3 control maximum value, Eco
38 HINOR_TEMP_FAN1_MIN 22 FAN1 temperature to start the control, HighLand Normal
39 HINOR_TEMP_FAN1_MAX 32 FAN1 temperature to end the control, HighLand Normal22
40 HINOR_TEMP_FAN2_MIN 22 0~255 FAN2 temperature to start the control, HighLand Normal
41 HINOR_TEMP_FAN2_MAX 32 FAN2 temperature to end the control, HighLand Normal
42 HINOR_TEMP_FAN3_MIN 22 FAN3 temperature to start the control, HighLand Normal
43 HINOR_TEMP_FAN3_MAX 32 FAN3 temperature to end the control, HighLand Normal
44 HINOR_VALU_FAN1_MIN 90 FAN1 control minimum value, HighLand Normal (0:Fan voltage 0V, 255:Fan voltage 25.5V)
45 HINOR_VALU_FAN1_MAX 138 FAN1 control maximum value, HighLand Normal
Electrical Adjustments
No. Adjustment Item Initial Value Range Input source / Description