If you are connecting directly to an In-Sight sensor or In-Sight PC Host:
1 Plug one of the RJ-45 connectors on a CAT5 cable into the ENET port on the
In-Sight 4000.
2 Plug the other end of the CAT5 cable into the crossover coupler (P/N 185-0080).
3 Connect the crossover coupler into the other system’s Ethernet port.
2.1.2 Connecting the Breakout Cable
The In-Sight Breakout Cable (P/N 300-0340-15/30) included with every In-Sight sensor
provides access to the In-Sight 4000 sensor’s power, serial communications, and I/O
lines. The RJ-45 connector on this cable is “keyed” to the notch in the breakout port,
and cannot be inadvertently plugged in to the network port.
See Section 3.2.1: Breakout Port Pin Assignments on page 30 for the Breakout Cable’s
wiring details.
To connect the Breakout Cable to the In-Sight 4000:
1 Verify the 24VDC power supply being used is switched off.
2 Attach the Breakout Cable’s power (white-green wire) and ground (brown wire) to
the corresponding terminals on the power supply.
3 Connect the wires for the acquisition trigger, discrete outputs, and serial
communications to their corresponding terminals on remote devices.
4 Plug the RJ-45 connector into the In-Sight 4000 sensor’s breakout port (labeled
24VDC).
5 Restore power to the 24V supply. The green power LED will indicate that the 4000
is receiving power.