11
10. Hold motor shaft with 7/16" open end wrench on
shaft flats and screw impeller onto shaft. Be sure
you do not touch capacitor terminals with body
or any metal object. Tightening impeller will
automatically locate seal in correct position.
11. Remount diffuser on pump body half with five
screws.
12. Follow instructions under “Pump Reassembly”.
PUMP REASSEMBLY
1. Clean O-ring and O-ring groove.
2. Put O-ring in groove on face of flange; put pump
halves together (see Figure 27).
3. BE SURE inside of clamp is clean. Place clamp on
pump halves; snug up. Alternately tighten nut and
tap clamp with mallet to seat O-ring (see Figure 28).
4. Replace base mounting bolts.
5. Replace pressure switch tubing and motor wiring;
close draincock.
6. Prime pump according to instructions.
See “Operation.”
7. Check for leaks.
Maintenance (Continued)