82 Administrator’s Guide
BMC Atrium Integration Engine 7.1.00
-102
Unable to create buffer for the event request.
The event-driven interface ran out of available memory and was unable
to create a request block to transmit the request. The processing cannot
continue. This is a fatal error.
-103
AR Initialization failed. Verify login information is
correct.
The event-driven interface was unable to connect to the AR System server
identified by the parameters. Verify the AR System server login
parameters. If the parameters are correct, verify that the AR System
server is running.
-104
Failed to submit event request. ARCreateEntry returns error.
The event-driven request could not be submitted to the Application
Pending form on the AR System server. Verify that the AR System server
identified in the startup parameters has the Data Exchange application
installed.
-201
Unable to retrieve host name and port for EIE service. Make
sure the AR System user name and password are correct.
The event-driven request has been submitted, but the Integration Engine
service could not be notified to handle the request. The Integration Engine
service sets the wakeup port information in the EIE:BackupLoadFlag
form. If the values are not set, no active Integration Engine service exists
to handle the request at this time.
-202
EIE service wakeup port not set in EIE:BackupLoadFlag form.
The event-driven request has been submitted, but the Integration Engine
service could not be notified to handle the request. The Integration Engine
service sets the wakeup port information in the EIE:BackupLoadFlag
form. If the values are not set, no active Integration Engine service exists
to handle the request at this time.
-203
Unable to create socket.
-204
Unable to establish socket connection to EIE service.
The event-driven request has been submitted, but the Integration Engine
service could not be notified to handle the request. A socket connection to
the Integration Engine service has been identified in the
EIE:BackupLoadFlag form, but the socket connection could not be
established.
-205
Unable to send immediate request to EIE service.
The event-driven request has been submitted, but the Integration Engine
service could not be notified to handle the request. A socket connection to
the Integration Engine service has been established, but the wakeup
request could not be sent.
-301
Unable to access Event Request form to obtain response.
The event-driven request has been submitted, and the Integration Engine
service has been notified to handle the request. The Application Pending
form could not be accessed to obtain the completion status.
Table 4-7: eiexfer completion code messages
ID Number Message