Weslo WATL27105.1 Treadmill User Manual


 
8
6
. Carefully pull the opposite end of the tape to pull the
W
ire Harness (60) up through the Right Handrail (59)
and out of the hole in the side of the Right Handrail.
Remove the tape from the Wire Harness (60).
59
Tape
6
0
6
7. Orient the Crossbar (91) with the large hole at the right
of the smaller hole as shown. Set the Crossbar against
the Handrails (53, 59) with the brackets on the Crossbar
aligned with the two small holes in each Handrail. Attach
the Crossbar with two Crossbar Star Washers (93) and
two Crossbar Screws (92).
Do not tighten the
Crossbar Screws yet.
With the help of as second person, hold the console
assembly near the Crossbar (91). Connect the pulse
wire from the Crossbar to the pulse wire from the con-
sole assembly. The connectors should slide easily into
each other and snap into place. If they do not slide easi-
ly and snap into place, turn a connector and then insert it.
Insert the ground wire through the two plastic ties shown
in step 8. Attach the end of the ground wire to the small
hole in the side of the Right Handrail (59) with a Silver
Ground Screw (69).
Pulse
Wires
Console
Assembly
59
69
53
92
91
92
93
93
7
52
Ties
59
8
8. Place the Console Base (52) on the Crossbar (91), Right
Handrail (59) and the Left Handrail (not shown). Be care-
ful not to pinch any wires. Attach the Console Base with
four 3/4” Screws (2) (only two Screws are shown). Do not
overtighten the Screws.
Insert the Wire Harness (60) through the two indicated
plastic ties on the Console Base (52). Next, touch the
Right Handrail (59) to discharge any static. See the
inset drawing. Insert the connector on the end of the W
ire
Harness into the red socket beneath the console. The
connector should slide easily into the socket and snap
into place. If the connector does not slide easily and snap
into place, turn the connector and then insert it.
Make sure that the connector and wire appear as shown
in the inset drawing. IF THE CONNECTORS ARE NOT
INSERTED PROPERLY, THE CONSOLE MAY BE
DAMAGED WHEN THE POWER IS TURNED ON.
60
2
Socket
60
Ground
Wire
91