Vision Fitness T9250 Treadmill User Manual


 
33
GENERAL
AUTO-CALIBRATION
(Models T9350HRT & T9450HRT Only)
DO NOT STAND ON THE BELT WHEN PERFORMING THE AUTO-CALIBRATION!
Auto-calibration is not represented by a Px designation. "Auto" appears in
the center window. When you enter the function, "Auto" begins flashing.
To begin auto-calibration, press START. The treadmill will run through
minimum and maximum speed and maximum incline, this will take three to
five minutes. Let the treadmill perform this complete function before exiting
the Engineering Mode.
Elevation A/D or Elevation in % appears in the left window. PWM value
or Speed appears in the right window. "End" will appear in the center
window when the auto-calibration is complete. When auto-calibration is
complete, it will take about 30 seconds to go to 0 elevation and return to
the start-up screen with P1 showing in the function window.
EXIT USER ENGINEERING MODE
P14 represents exit mode. When you press START to select the function,
the console performs a reboot, returning to program setup.
AUTO CALIBRATION
(Model T9250 Only)
DO NOT STAND ON THE BELT WHEN PERFORMING THE AUTO-CALIBRATION
Hold the Elevation Up and Speed Down buttons for 5 seconds. The
console will beep 5 times and a number will appear in the window.
Shortly thereafter, EnG1 will appear in the window.
Press the Elevation Up or Speed Up to EnG4
Press Start. The treadmill will calibrate itself. It will take 3-5 minutes. When
the Auto Calibration is complete "END" will flash in the window. Wait 10
seconds.
Remove the Safety Key, then put the Safety Key in place to use the treadmill.