Star Trac 7600 Treadmill User Manual


 
Service Manual: E-TR and E-TRi
26
DISPLAY PARAMETERS
Parameter Defaults
The following parameters can be accessed by entering the Maintenance Mode. When installing a
new display electronic board, it will come with factory default settings. Depending on the model and
voltage of unit you are installing the board into, you may need to adjust your settings by referencing
the following chart.
Parameter 110V Setting 220V Setting Default Parameter Ranges
UNITS
ENGLISH ENGLISH, METRIC
MINIMUM SPEED
0.5
(0.8kph)
0.5
(0.8kph)
0.5
(0.8kph)
0.5 – 5.0
(0.8 – 8.0kph)
MAXIMUM SPEED
10.0
(16.0kph)
12.0
(20.0kph)
12.5
(kph)
5.0 – 12.5
(8.0 – 20.0kph)
ELEVATION
ON OFF, ON
TIME
99 20 - 99
OPER HOURS
0 0 – 65535
DISTANCE
0 0 – 65535
WEIGHT
155 0 – 350
SERIAL NO
0 0 – 65535
LANGUAGE
ENGLISH ENGLISH, DUTCH, FRENCH,
GERMAN, PORTUGUESE,
SPANISH, SWEDISH, ITALIAN,
KATAKANA
ENTRY
UNITS UNITS, TENTHS
HEART RATE
BOTH CONTACT, POLAR, BOTH
METS
OFF OFF, ON
WATTS
OFF OFF, ON
PAUSE
45 20 – 120
SCALE
ON OFF, ON
INFRARED COM
ON OFF, ON
CSAFE
ON OFF, ON
FAN
ON OFF, ON
AUTO STOP
OFF OFF, ON
ENTERTAINMENT
OFF OFF, ON
ACCELERATION TIME
35 25 – 60
DECELERATION TIME
30 20 - 60
LOCK OUT
OFF OFF, ON
LOCK OUT ID
12345 0 - 65535
RAIL STOP
ON OFF, ON
STOP SWITCH
E-STOP E-STOP, LANYARD
10_REV
376 376 376 0 – 740
CNT/REV
31 31 31 0 – 125
MINUMUM PWM
(VARIES) (VARIES) 34 0 – 110
1/2 MAXIMUM
(VARIES) (VARIES) 200 0 – 340
MAXIMUM PWM
(VARIES) (VARIES) 400 0 – 495
PERSON DETECT 1
17 17 17 0 – 150
PERSON DETECT 2
30 30 30 0 – 150
PERSON DETECT 3
40 40 40 0 – 150
DATE
1.98 0.00 – 9.99