18
Before the cadence sensor is securely fastened to the flywheel support
, it must be adjusted
so
that it is about 5 mm (.20 in) from the magnet face. Install the magnet on the flywheel so
that it aligns with the arrow
on the end of the cadence sensor. Note the distance between the
end of the cadence sensor and the magnet face. Remove the cadence br
acket and adjust
the distance by pulling or pushing the cadence sensor bracket.
Tighten the set screw on the cadence mounting bracket using the M2 Allen tool
Caution
Do not over tighten the set screw.
Magnet location
Remove the backing of the adhesive on the magnet.
Mount the magnet with the adhesive
tape side onto the flywheel by positioning the magnet so it will line up in front of the cadence
sensor as the flywheel turns. Note: Mount the magnet near one of the dots of the Sp
inning
logo as shown in the figure above.
Installation of Cadence Sensor and Magnet All Spinners®