Pentax R-335(N) Home Gym User Manual


 
PSF Software Ver.365
27
6 COORDINATES
General pictures of measurement
Any desired Target coordinates can be determined and stored by setting a Station Point as an
original point and inputting the Backsight coordinate in COORDINATES measurement. The
coordinates values from Original coordinates point can be determined by the Station coordinates
input even if the Station Point is not set as original point. Coordinates values input can be omitted
by designating the Station Point No. whenever the Station coordinates are stored in the internal
memory.
General pictures
Z
N
Target
Backsight Point
Target
Station Point
E
Detailed Operating procedures
Access the COORDINATES according to " ACCESSING THE SPECIAL FUNCTIONS ".
1. JOB NAME
(1) JOB NAME input ( Selection keys:
,,,
)
1.JOB NAME
ENT
COORDINATE JOB NAME INPUT
ENT
JOB NAME input by pressing selection keys
ENT
(2) JOB NAME selection ( Selection keys:
,,,
)
1. JOB NAME
ENT
COORDINATES JOB NAME INPUT
Select the JOB NAME by shift keys
ENT
To the primary screen of the COORDINATES
The JOB NAME can be selected only when the JOB NAMES are already stored.