PSF Software Ver.365
11
3 COORD. STAKEOUT
General pictures of measurement
With COORD. STAKEOUT measurement, "Stakeout point coordinates" can be staked out in 3
dimensions based on the known "Station point coordinates" and the "Backsight point coordinates
or Backsight point azimuth". The horizontal angle, horizontal distance and vertical distance to the
stakeout point are automatically calculated as design values, and the differences between the
measured values and design values are displayed as deviations. When the coordinate values of
the Station point, Backsight point and Stakeout point are recorded on the instrument memory,
designation of each measured point number makes it possible to omit the each time coordinates
value input.
General pictures
Z
N
Prism height
B
acksight point
Staking point
Instrument height
Station point
E
Design values and deviation
N Z
Distance deviation
Prism
Z deviation
Horizontal distance
design value
Staking point
Prism
Horizontal angle
design value Staking point
Station point
Horizontal angle
deviation
Backsight point
Z design value
Backsight point azimuth
Station point
E E