Newcon Optik DN 463 Hunting Equipment User Manual


 
12
8. SIGHTING DN463
Sighting in of the scope should be done at operating
temperatures, by following the order of these steps:
Mount the rifle with the scope installed on a bench
rest.
Make sure that no sources of light are visible through
the scope's field of vision.
Set a target at a distance of about 100m; the light
levels around the target should not exceed 1 lux.
Remove the objective lens cap (2), by sliding it up on
top of the objective lens.
Turn on the scope by turning the selector switch (3)
to the “ON” position.
Aim the firearm at the target using the mechanical
sight.
Adjust the scope according to the steps in the section
entitled “OPERATING INSTRUCTIONS”.
Turn the objective lens focusing knob (6) until you
get a crisp image of the target.
Set the desired reticle brightness level by turning
knob (4).
If the center of the reticle crosshairs and the target
center do not line up, remove the covers protecting
the windage / elevation adjustment knobs.