Maintenance:
9.14 Changing the suction filter
The suction fi lter „S“ must be changed after every hydraulic oil change and every 1000 operating hours.
9.15 Adjusting the stripper
• Loosen all three bolts „S“ and push the stripper towards the drum.
• The distance between the stripper and the drum must be at least 2 mm.
• Tighten bolts „S“ again. (Fig. 41)
Remark:
In case of stripper wear (two strippers each per drum) these must be readjusted or replaced.