Maintenance:
9.14 Changing the suction filter
The suction fi lter „S“ must be changed after every hydraulic oil change and every 1000 operating hours.
9.15 Adjusting the stripper
Loosen all three bolts „S“ and push the stripper towards the drum.
The distance between the stripper and the drum must be at least 2 mm.
Tighten bolts „S“ again. (Fig. 41)