Maintenance:
9.09 Changing the transmission oil
Unscrew magnetic plug „M“ and clean. (Fig. 33)
Release the fastening screws „B“ on the transmission cover.
Screw puller bolts into thread „A“ (M8x25 DIN 933-8.8) and pull off the transmission cover.
Transmission oil: Titan Gear MP 80
Note:
Collect the transmission oil in a suitable container and dispose of in an environmentally responsible manner
Wash out the drive system and remount the
transmission cover (the gasket on the transmission
cover must not be damaged).
Top up transmission oil through the magnetic plug
opening (1.1 litres) and screw the cleaned magnetic
plug back in.
Check the drive system for leaks.
9.10 Checking / cleaning / replacing the air fi lter
Replace air fi lter cartridge:
Release the sealing cap „D“ from the air fi lter housing
and remove air fi lter cartridge „P“.
After inserting the cleaned or new fi lter cartridge, mount
the sealing cover „D“. (Fig. 34)
Note:
Never use petrol or hot fl uid to clean the fi lter cartridge!!!
After cleaning, the fi lter cartridge must be examined for damage using a lamp. Filter cartridges which are damaged at
the seal or at the cartridge itself must be exchanged without fail. The fi lter cartridge of the air fi lter must be exchanged
after being cleaned three times or after a year at the latest. If the fi lter cartridge is contaminated with sooty deposits,
cleaning is not possible. Use a new cartridge. Each completed cleaning process of the fi lter cartridge must be
documented on the lid of the cartridge. Insuffi cient cleaning and handling of the fi lter cartridge can lead to serious
damage to the engine!!!
Dry cleaning:
i Danger to the eyes!
Wear protective clothing (protective goggles, gloves)
Blow through the fi lter cartridge using dry compressed air (max. 5 bar) from the inside to the outside.
Wet cleaning:
Clean the fi lter cartridge by waving backwards and forwards in lukewarm water using a standard
commercially available mild detergent. Then rinse well in cold water, shake out and leave to dry well.