Graco 500 Cyclometer User Manual


 
Edge 500 Owner’s Manual 27
ANT+ Sensors
GSC 10 and Magnet
Alignment
Spoke
magnet
Sensor arm
indication line
Pedal
magnet
GSC 10
6. Loosen the screw on the sensor
arm.
7. Move the sensor arm to within
5 mm of the spoke magnet.
You can also tilt the GSC 10 closer
to either magnet for improved
alignment.
8. Press the
Reset button on the
GSC 10.
The LED turns red, then green.
9. Pedal to test the sensor alignment.
The red LED blinks each time the
pedal magnet passes the sensor.
The green LED blinks each time
the spoke magnet passes the sensor
arm.
NOTE: The LED blinks for the rst
60 passes after a reset. Press Reset
again if you require additional
passes.
10. When everything is aligned and
working correctly, tighten the cable
ties, the sensor arm, and the spoke
magnet.