To nd the uid pressure (psi/bar/MPa) at a specic
uid ow (gpm/lpm) and percentage of maximum
force:
1. Locate the desired uid ow in the scale at the
bottom of the chart.
2. Follow the vertical line up to the intersection with
the selected percentage of maximum force (see
the KeyKey
Key
below).
3. Follow left to the vertical scale to read the uid
outlet pressure.
KeyKey
Key
toto
to
PerformancePerformance
Performance
ChartsCharts
Charts
NOTE:NOTE:
NOTE:
The charts show the motor operating at
100%, 70%, and 40% of maximum force. These
values are approximately equivalent to an air motor
operating at 100, 70, and 40 psi.
100% of maximum force
70% of maximum force
40% of maximum force
TableTable
Table
22
2
..
.
ModelsModels
Models
EC11xxEC11xx
EC11xx
andand
and
EC12xxEC12xx
EC12xx
(750(750
(750
cccc
cc
lower,lower,
lower,
11
1
HPHP
HP
motor,motor,
motor,
14001400
1400
lblb
lb
maximummaximum
maximum
force)force)
force)
CYCLESCYCLES
CYCLES
PERPER
PER
MINUTEMINUTE
MINUTE
NOTE:NOTE:
NOTE:
The shaded area within the table shows the recommended range for continuous duty circulation
applications.
FLUIDFLUID
FLUID
PRESSURE:PRESSURE:
PRESSURE:
psi (bar, MPa)
FLUIDFLUID
FLUID
FLOW:FLOW:
FLOW:
gpm (lpm)