Operation
OperationOperation
Operation
StartupStartup
Startup
To operate the pump, follow the Startup instructions
for the Basic or Advanced motor in the Motor manual.
The Advanced E-Flo DC motors require installation of
the 24P822 Control Module Accessory Kit to provide
the interface for users to enter selections and view
information related to setup and operation. See the
Control Module Accessory Kit manual for installation
and operation information.
Run the pump at a slow speed until the uid lines are
primed and all air is forced out of the system.
ShutdownShutdown
Shutdown
Follow the Pressure Relief Procedure, page 13.
PressurePressure
Pressure
ReliefRelief
Relief
ProcedureProcedure
Procedure
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from splashing uid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
1. Disengage the start/stop control (C). See Fig. 1.
2. Shut off and lock out the fused safety switch (B).
3. Open the uid drain valve (D), having a waste
container ready to catch drainage. Leave open
until you are ready to pressurize system again.
3A2096D13