User Command Specifications
9.Details of command RANGE LAMP
RANGE LAMP
RANGE LAMP
RANGE□LAMP
r:LAMP=I, <Setting option 1>, <Setting option 2>, …, <Setting option n>
-1
A "busy" response is given while the zoom or focus lens is being driven.
-2
> RANGE LAMP
< r:LAMP=I, NORMAL, SILENT
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command State
OFF ON PM
× ○ ×
× ○ ×
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
Command
supported
Setting Reference
For all other responses, refer to "Error List."
This inquiry can be made when the projector is in both the remote mode and power-on status
at the same time.
○○
X600
SX60
○○○×○○○○
SX6
○○○
– ○○×○○○–
SX50
○○○
S-Video D-Video SCART None
Mode
Remote Local
Remarks
Model Power
Input
D-RGB A-RGB1 A-RGB2 Comp Video
01.00** 01.01** 01.01** 01.01**
○○
Mode Control
(Refer to the ZCONTDRV command and FCONTDRV command.)
The lamp output can be set by the LAMP command.
Lamp output setting option reques
SX60 X600
This inquires about the parameter options which enable the lamp output to be set.
ID
SX50 SX6
Example
Description
Response
Commands
Function
Format