![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/cf/4cfc1a8f-0b4a-4cdd-bb6f-f6319497b612/4cfc1a8f-0b4a-4cdd-bb6f-f6319497b612-bg8d.png)
User Command Specifications
9.Details of command RANGE TRACK
RANGE TRACK
RANGE TRACK
RANGE□TRAC
r:TRACK=N, <Minimum setting value>, <Maximum setting value>
-1
A "busy" response is given while the zoom or focus lens is being driven.
With some input signals, it may not be possible to make this inquiry.
-2
> RANGE TRACK
< r:TRACK=N, 0, 31
* Commands are indicated by ">", and responses are indicated by "<".
Supported Command State
OFF ON PM
× ○ ×
× ○ ×
* If the command cannot be supported, 'INVALID_MODE,' 'NOT_POWER_SUPPLIED' or 'INVALID_SOURCE' is returned as an error response.
* If the necessary signals are not input, 'INVALID_SIGNAL (*****)' or 'NO_SIGNAL' is returned.
* "i:BUSY" may be returned if the power status is being switched.
For all other responses, refer to "Error List."
This inquiry can be made when the projector is in both the remote mode and power-on status
at the same time.
(Refer to the ZCONTDRV command and FCONTDRV command.)
Command
supported
X600
SX60
××○ ×××××
SX6
× ○○
–×○ ×
SX50
× ○○
Remarks
D-RGB A-RGB1 A-RGB2 Comp Video S-Video D-Video SCART None
Model Power
Input Mode
Remote Local
○○○○
01.01**
Tracking adjustment range reques
Mode Control Setting ReferenceCommands
Function
Format
Example
Description
Response
Number
×××–
This inquires about the values to which the tracking can be adjusted.
01.00** 01.01** 01.01**
The tracking adjustment can be set by the TRACK command.
SX60 X600SX50 SX6
PAGE 133