STAR TRAC TOTAL BODY TRAINER OWNER’S MANUAL 27
CHR Prog 0 65535 0 Number of times the Constant Heart Rate Control Program was run since last reset.
CW Prog 0 65535 0 Number of times the Continuous Watts Program was run since last reset.
Alpine 0 65535 0 Number of times the Alpine Pass Program was run since last reset.
Rndm Prog 0 65535 0 Number of times the Random Hill Program was run since last reset.
UB Revs 0 65335 0 Number of times the upper body system completed a full revolution.
Comm Lost 0 65535 0 Number of times a “Communication Lost” condition occurred since last reset.
Key Down 0 65535 0 Number of times a “Key Down” condition occurred since last reset.
BATT LOW 0 65535 0 Number of times battery voltage measured between 5.3 and 5.7 volts.
REPL BATT 0 65535 0 Number of times battery voltage measured below 5.3 volts.
LED Test N/A N/A N/A Access to integral LED test function (for use by authorized Maintenance Technician).
Keypad Test N/A N/A N/A Access to integral keypad test function (for use by authorized Maintenance
Technician).
Heart Rate N/A N/A N/A Access to integral heart rate system test function (for use by authorized
Test Maintenance Technician).
Measurements N/A N/A N/A Access to integral Measurements function (for use by authorized Maintenance
Technician).
UB N/A N/A N/A Access to integral Upper Body system calibration function (for use by author
CALIBRATION ized Maintenance Technician) - displays only when Model is set to P-TBTX CT.
STAR TRAC TOTAL BODY TRAINER
perform a self-test at the beginning of every workout. If a problem is detected, a message displays
before or after the workout, depending on the nature of the problem. Star Trac recommends that you refer your questions about your
STAR
TRAC TOTAL BODY TRAINER
operation and suspected malfunctions to Star Trac’s Service Hotline at (800) 503-1221, or USA 1-714-669-
1660.
START-UP SERVICE MESSAGES
The following messages are displayed at the beginning of a workout if the associated problem is detected during self-test.
■
Key Down - One or more keys on the display panel are stuck in the “on” position. This can occur if a user presses keys before the
system is turned on, or if a key is held down for more than 10 seconds. Call Star Trac Product Support for assistance if the Key Down
message continues to display.
TROUBLESHOOTING