Star Trac E-TR Treadmill User Manual


 
*When the MINIMUM SPEED or MAXIMUM SPEED parameters are changed, the Treadmill will perform an auto calibration. To termi-
nate the auto calibration and return the parameter to its default setting, press the S
TOP key.
MOTOR CALIBRATION
The Motor Calibration function allows for calibration of the treadmill's speed function. CAUTION: Changing Max Speed setting may
expose users to increase risk. Any changes to the treadmills maximum speed settings should be clearly communicated to all users of
the treadmill. To enter the Motor Calibration function:
1. While in the Maintenance Mode, press the key, or navigate to the Motor Calibration by the next or the previous
parameter buttons .
2. While in the Motor Calibration, press the key to begin the calibration. The information window will display “PWM= XXXXXX
SPEED=XX.X” where the X’s are data the that test will generate.
When the test is finished the information window will display one of the 2 messages “Passed Calibration” or “Failed Calibration”.
If “Failed Calibration” is displayed run test again, if it continues, call for maintenance.
3. Press the S
TOP key to exit the Motor Calibration function.
Lowest Default Highest
Item Value Value Value Meaning
DATE 1.00 1.98 12.99 Treadmill manufacture date.
STOP SWITCH - - - Either E-Stop or Lanyard.
LAST DECK 0 0 65,535 Number of miles (UNITS=English), or km (UNITS=Metric) since the running deck
was last serviced or replaced.
LAST BELT 0 0 65,535 Number of miles (UNITS=English) or km (UNITS=Metric) since the running belt
was last replaced.
PROGRAM - - - Provides access to programs usages and counters. (See Sub Menu)
STATS
LED TEST - - - LED Testing function, Press OK to begin
KEYPAD TEST - - - LED Testing function, Press OK to begin.
HEART RATE - - - HEART RATE Test function.
TEST
SERIAL PORTS - - - RS 232 Ports test (Manufacture Test Only).
TEST
ERROR STATS - - - Provides Access to Error List.
LAST ERROR - - - Last Error List Menu, Press OK to View
LIST
CALIBRATION - - - Provides Access to View Calibration Data.
VALUES
MOTOR - - - Motor Calibration Function, Press OK to begin.
CALIBRATION
ELEV - - - Elevation Calibration Function, Press OK to begin.
CALIBRATION
BURN IN - - - Burn In Mode Function (Manufacture Only).
MODE
40
STAR TRAC E SERIES TREADMILL O
WNERS MANUAL