Disassemble the Equipment
This unit arrives fully assembled except for the shrouds and the bottle
holder/accessory tray. In some cases, you may need to disassemble the
unit before you move it.
WARNING: You will need assistance to disassemble this unit. The weight
tower is unstable when disconnected from the exercise station. Make
sure the weight tower is supported safely during disassembly. Do not
attempt disassembly by yourself.
To Detach the Cable:
1. Loosen the locking jam nut and unscrew the bolt in the center of the
top weight cap using a ³₄” open-end wrench.
2. Route the cable through the top of the weight tower and down to the
lower 6” pulley.
3. Remove the shoulder bolt from the 6” pulley using a ¹₄” hex key.
4. Unfasten the 6” pulley and unthread the cable.
Note: Remove the pulley cable from the weight stack and keep it
attached to the exercise station.