7
4. Cut the tie securing the Pulse Wire (74) to the right
Upright (20). Hold the Pulse Bar Assembly (69) near the
crossbar on the Uprights. Connect the Pulse Wire to the
wire in the Pulse Bar Assembly. The connectors should
slide together easily and snap into place. If they do
not, turn one connector and try again. Then, insert the
wires into the crossbar.
Open parts bag B. Attach the Pulse Bar Assembly (69)
to the crossbar on the Uprights (20) with four Pulse Bar
Bolts (13) and four Star Washers (67). Start all four Pulse
Bar Bolts before tightening them. Make sure that no
wires are pinched.
Crossbar
74
13
13
69
20
67
67
74
2. With the help of a second person, raise the Uprights (20)
to the vertical position.
Remove the knob from the pin. Make sure that the collars
a
nd the spring are on the pin. Next, press the Latch Insert
(77) into the left Upright (20). Use a rubber mallet if nec-
essary. Then, insert the pin into the Latch Insert, and
tighten the knob back onto the pin.
7
7
2
Knob
20
Pin
Collar
Spring
3. With the help of a second person, raise the Walking
Platform (15) to the storage position and engage the
latch pin as described on page 28.
Next, position the Base Plate (126) on the treadmill as
shown.
Attach the Base Plate with three Base Plate
Bolts (125). Note: It may be helpful if a second person
tips the treadmill slightly as you tighten the Bolts.
If the treadmill rocks slightly, turn one or both of the
Leveling Feet (130) under the Uprights (20) until the
rocking motion is eliminated (see page 31). Carefully
lower the Walking Platform (15) to the floor as described
on page 29.
126
15
125
20
130
130
3