Life Fitness 97T1 Treadmill User Manual


 
1.2 SETUP
Read the Operation Manual before setting up the Life Fitness Treadmill. Place the treadmill where it will be used before
beginning the setup procedure.
ELECTRICAL POWER REQUIREMENTS
The Life Fitness Treadmill requires a dedicated* line with isolated neutral according to the electrical configurations listed
in the chart below.
* One individual branch circuit for each treadmill per NEC article 210-21 (b) (1) and 210-23 (or other appropriate, country specific electrical compliance
guidelines). The hot and neutral wires must each be routed independently (not looped or tied to other circuits)" .
Note: Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet, have a
proper outlet installed by a qualified electrician.
GROUNDING INSTRUCTIONS
This Life Fitness product must be properly grounded. If the unit malfunctions or breaks down, proper grounding provides
a path of least resistance for the electric current, which reduces the risk of shock to anyone touching or using the equip-
ment. Each unit is equipped with an electrical cord, which includes an equipment grounding conductor and a grounding
plug. The plug must be inserted into an outlet that has been properly installed and grounded in accordance with all local
codes and ordinances.
A temporary adapter MUST NOT BE USED to connect this plug to a two-pole receptacle in North America. If a
properly grounded, 20-amp outlet is not available, one must be installed by a qualified electrician. Models
drawing 16 amps or more must be installed on a dedicated line.
IL EST ABSOLUMENT INTERDIT d'employer un adaptateur temporaire pour brancher cette fiche sur une
prise bipolaire en Amérique du Nord. Si aucune prise de 20 A correctement mise à la terre n'est disponible,
en faire installer une par un électricien qualifié. Les modèles utilisant 16 A ou plus doivent être branchés sur
un circuit spécialisé.
DANGER: A risk of electrical shock may result from improper connection of the equipment-grounding con-
ductor. Check with a qualified electrician if in doubt as to proper grounding technique. DO NOT modify the
plug provided with the product. If it will not fit an electrical outlet, have a proper outlet installed by a qualified
electrician. Any modification to the electrical plug will result in a voided warranty.
Un branchement incorrect du conducteur de mise à la terre peut entraîner des risques de décharge électrique.
Consulter un électricien si des doutes subsistent quant à la technique de mise à la terre. NE PAS MODIFIER la
fiche fournie avec l'appareil. Si elle ne s'adapte pas à une prise, faire installer une prise correcte par un électricien
qualifié. Toutemodification à la fiche annule la garantie.
9