Inter-Tel PATL41106.0 Treadmill User Manual


 
9
H
OW TO PUT ON THE CHEST PULSE SENSOR
T
he chest pulse sensor consists of two components:
the chest strap and the sensor unit (see the drawing
below). Insert the tab on one end of the chest strap into
the hole in one end of the sensor unit, as shown in the
inset drawing. Press the end of the sensor unit under
the buckle on the chest strap. The tab should be flush
with the front of the sensor unit.
Next, wrap the chest
pulse sensor around
your chest and attach
the other end of the
chest strap to the
sensor unit. Adjust
the length of the
chest strap, if neces-
sary. The chest pulse
sensor should be under your clothes, tight against your
skin, and as high under the pectoral muscles or
breasts as is comfortable. Make sure that the logo on
the sensor unit is facing forward and is right-side-up.
Next, pull the sensor unit away from your body a few
inches and locate the two electrode areas on the inner
side (the electrode areas are covered by shallow
ridges). Using saline solution such as saliva or contact
lens solution, wet both electrode areas. Return the
sensor unit to a position against your chest.
CHEST PULSE SENSOR CARE AND MAINTENANCE
Thoroughly dry the chest pulse sensor after each
use. The chest pulse sensor is activated when the
electrode areas are wetted and the heart rate
monitor is put on; the chest pulse sensor shuts off
when it is removed and the electrode areas are
dried. If the chest pulse sensor is not dried after
each use, it may remain activated longer than nec-
essary, draining the battery prematurely.
Store the chest pulse sensor in a warm, dry place.
Do not store the chest pulse sensor in a plastic bag
o
r other container that may trap moisture.
Do not expose the chest pulse sensor to direct sun-
l
ight for extended periods of time; do not expose it to
temperatures above 50° C (120° F) or below -10° C
(15° F).
Do not excessively bend or stretch the sensor unit
when using or storing the chest pulse sensor.
Clean the sensor unit using a damp cloth—never
use alcohol, abrasives, or chemicals. The chest
strap may be hand washed and air dried.
CHEST PULSE SENSOR TROUBLESHOOTING
The instructions on the following pages explain
how the chest pulse sensor is used with the con-
sole. If the chest pulse sensor does not function
properly, try the steps below.
Make sure that you are wearing the chest pulse sen-
sor as described at the left. Note: If the chest pulse
sensor does not function when positioned as de-
scribed, move it slightly lower or higher on your chest.
Use saline solution such as saliva or contact lens
solution to wet the two electrode areas on the sensor
unit. If heart rate readings do not appear until you
begin perspiring, rewet the electrode areas.
As you walk or run on the treadmill, position your-
self near the centre of the walking belt. For the con-
sole to display heart rate readings, the user must
be within arm’s length of the console.
The chest pulse sensor is designed to work with
people who have normal heart rhythms. Heart rate
reading problems may be caused by medical condi-
tions such as premature ventricular contractions
(pvcs), tachycardia bursts, and arrhythmia.
The operation of the chest pulse sensor can be af-
fected by magnetic interference caused by high
power lines or other sources. If it is suspected that
this is a problem, try relocating the treadmill.
The CR2032 battery may need to be replaced (see
page 28).
Chest Strap
Tabs
Sensor Unit
Tab
Sensor
Unit
Buckle
HOW TO USE THE CHEST PULSE SENSOR