This appendix summarizes the management processor (MP) commands. In the examples, MP is
used as the command prompt.
NOTE: The term Guardian Service Processor has been changed to Management Processor, but
some code already written uses the old term.
BO Command
BO - Boot partition
Access level—Single PD user
Scope—partition
This command boots the specified partition. It ensures that all the cells assigned to the target
partition have valid complex profiles and then releases Boot-Is-Blocked (BIB).
Example B-1 BO command
CA Command
CA - Configure Asynchronous & Modem Parameters
Access level—Operator
Scope—Complex
There is one active RS232 port connection to the service processor’s textual user interface. This
RS232 connection is called the local RS232 port. The local RS232 port connects to a local terminal
or to the CE laptop.
NOTE: On the HUCB board, there is a remote RS232 connector. The remote RS232 system was
used to connect to a modem on legacy systems. Modem support is removed, so connections to
the remote RS232 connector are ignored.
This command enables you to configure the local and remote console ports. The parameters you
can configure are the baud rate, flow control, and modem type.
BO Command 149