Weslo WETL01540 Treadmill User Manual


 
8
MAINTENANCE AND TROUBLESHOOTING
Most problems can be solved by following the simple steps below. If further assistance is needed,
p
lease call our Customer Service Department.
1. SYMPTOM: THE CONSOLE DOES NOT
FUNCTION PROPERLY
a. Replace the batteries in the console (see assem-
bly step 6 on page 5).
b. Make sure that the reed switch is properly adjust-
ed (see assembly step 4 on page 4).
c. Make sure that the handrail wire is plugged fully
into the wire on the console (see assembly step 7
on page 5).
d. The console, like most electronics, is susceptible
to static electricity build-up caused by certain
types of clothing or by the operation of the tread-
mill. If the display is blank or gives incorrect read-
ings, apply an anti-static spray to the handrail.
Anti-static spray is available where laundry sup-
plies are sold.
2. SYMPTOM: THE WALKING BELT DOES NOT
MOVE SMOOTHLY
a. If the walk-
ing belt is
overtight-
ened, per-
formance
may be
reduced and
the walking
belt may be
permanently
damaged.
Using the
hex key,
turn both rear roller adjustment bolts counter-
clockwise 1/4 of a turn. When the tension of the
walking belt is correct, you should be able to lift
each side of the walking belt
5 to 7 cm (2 to 3 in.).
W
alk on the treadmill for a few minutes.
Repeat
until the walking belt is properly tightened. Be
careful to keep the walking belt centred.
3. SYMPTOM: THE WALKING BELT SLIPS OR IS
OFF-CENTRE
a. If the walking
belt slips
when walked
on
, use the
hex key to turn
both adjust-
ment bolts
clockwise, 1/4
of a turn. When
the walking belt is correctly tightened, you should
be able to lift each side of the walking belt 5 to 7
cm (2 to 3 in.). Walk on the treadmill for a few
minutes. Repeat until the walking belt is properly
tightened. Be careful to keep the walking belt cen-
tred.
b.
If the walking
belt has shift-
ed to the left
side, use the
hex key to turn
the left adjust-
ment bolt
clockwise, and
the right adjust-
ment bolt counterclockwise, 1/4 of a turn each.
Be careful not to overtighten the walking belt.
Walk on the treadmill for a few minutes. Repeat
until the walking belt is centred.
c.
If the walking
belt has shift-
ed to the right
side, use the
hex key to turn
the left adjust-
ment bolt coun-
terclockwise,
and the right
adjustment bolt clockwise, 1/4 of a turn each. Be
careful not to overtighten the walking belt. Walk
on the treadmill for a few minutes. Repeat until the
walking belt is centred.
5–7cm
Bolts
Walking