True Fitness 600EA Elliptical Trainer User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
NO DISPLAY
600EA
Power Issues
Control Panel
Power Supply
Cables
Set meter to AC voltage and test wall
outlet to 120 VAC.
Turn power switch on
Does power switch lamp come on?
Yes – go to control panel.
No- remove rear cover.
Check voltage input to switch, is it 120
VAC? If yes – replace switch. If no –
continue on.
Check voltage at end of power cord.
No voltage? Replace cord.
Check fuse in power inlet.
Replace fuse or replace power inlet and
wires.
--------
Check connection to the display.
Reseat connection.
Set meter to DC volts, unplug display
and check voltage between pin 1and pin
2.
If 12VDC is present – replace control
panel.
--------
Check voltage between pin 2and pin 3at
the power supply.
If 12 VDC present – replace power
supply.
--------
Perform a continuity check on the cables
leading to the control panel.
Replaced damaged cables.
Multi-meter
Page 13
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148