True Fitness 600EA Elliptical Trainer User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
NO POLAR
HEART RATE
750E, 750EA
600EA.
Control Panel
Defective Cables
Attach heart rate simulator around chest
or use Polar simulator.
Do not touch the hand pulse sensors.
Start pedaling
Check display for heart rate.
--------
Does console display heart rate with
chest strap?
Does console display heart rate with HR
simulator?
If unit responds with simulator and not
chest strap then replace chest strap.
If unit does not respond with strap or
simulator then replace Console set.
Note:
You must pedal at least
30 RPM when
p
erforming any voltage
test. You may require the
assistance of another
p
erson when performing
volta
g
e checks.
Polar Heart Rate
Simulator
Excessive radio,
electromagnetic or
audible noise can
cause poor heart rate
reception.
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148