True Fitness 455 Pediatric Treadmill User Manual


 
Symptom Probable Cause Corrective Action Recommended Tools
NO BELT
MOVEMENT
Treadmill in need of
calibration.
Missing command to
PWM.
Missing/incorrect
voltage to motor.
Damaged motor.
Run calibration. (page 14)
--------
Is PWM light blinking/ illuminated
when fast button is pushed?
NO- Check continuity on wire harness, if
harness has continuity breaks replace the
harness. If harness has continuity- replace
the upper panel. Refer to wiring harness
diagram for your model.
YES- move on to next step, wire harness and
control panel are OK.
--------
With treadmill in calibration mode
(page 14)
Set speed at 4 MPH
Check VDC across MTR 1 and MTR 2
with the motor leads connected to the
motor the voltage should measure 10
VDC for every 1 MPH.
If voltage is missing or low- Replace
PWM.
If voltage is greater than 20 VDC/MPH
motor may have open windings.
--------
With PWM LED Blinking/ Illuminated-
move the tread belt with your foot to see
if motor begins to move on its own.
If motor begins to move, inspect the
condition of the brushes and the
commutator.
If brushes are bad- replace brushes
If motor doesn’t turn or has a damaged
com segment- replace motor.
Continue on next page…
Multi-meter
PWM / Motor test
cables
Support Services 800-883-8783 Mon-Fri 8:30am-5:00pm Central Time Zone Fax: 636-272-7148