PREVENTATIVE MAINTENANCE
With durable, high performance components, the STAR TRAC E-ST STEPPER is designed for heavy usage with minimal maintenance
required. To keep your Stepper in top condition, Star Trac strongly recommends performing the regular daily, weekly and monthly pre-
ventive maintenance routines outlined below. Any unusual symptoms, such as a loud continuous noise during operation, should be
reported to STAR TRAC PRODUCT SUPPORT DEPARTMENT at (800) 503-1221, or USA 1-714-669-1660.
DAILY MAINTENANCE
Remove excessive accumulations of dust, dirt, and other substances by using a clean, soft cloth and a non-abrasive liquid cleaner,
such as Formula 409
TM
or FANTASTIK
TM
. Wipe down the exterior of the display panel, hand rails, pedals, shrouds and heart rate
grips.
NOTE: DO NOT spray the cleaner directly onto the Display Panel or heart rate grips.
WEEKLY MAINTENANCE
Perform the following services each week:
Vacuum the floor under and around the Stepper. Move the Stepper to another spot, if necessary, to vacuum thoroughly.
Inspect the Display Panel mounting screws for security, and retighten if necessary.
Inspect the Display Panel keypads for wear.
MONTHLY MAINTENANCE
Perform the following services each month, or as needed:
Check that the pedals and shrouds are secure.
Check the hand rails for looseness. Tighten screws as necessary.
Check for smooth and quiet operation of all moving parts.
MANAGER / MAINTENANCE MODE
After using your STAR TRAC E-ST STEPPER for a period of time, you may wish to change some of its settings.
MANAGER MODE
The Manager Mode lets you query and modify the basic settings of your Stepper. To enter Manager Mode:
1. Press and hold the
,
and keys together.
2. A beep will sound and “MANAGER MODE” will display momentarily in the Information Window.
3. Release all keys. “SERIAL NO #####” will display in the Information Window.
NOTE: The system will automatically exit Manager Mode if no key is pressed for 30 seconds.
The following keys are used to modify settings in MANAGER MODE:
Upper and Lower Data Information Window S
CROLL Keys: Display the next and previous parameters, respective-
ly.
Increase and Decrease L
EVEL Keys: Adjust the value of the displayed parameter up and down, respectively, in incre-
ments of 1 unit. These keys do not save the new value - see OK Key below.
Numeric Keypad: Allows you to enter specific values for numeric parameters. These keys do not save the new value
- see OK Key below.