Smooth Fitness 6.25E Treadmill User Manual


 
SMOOTH 6.25E MOTORIZED TREADMILL
www.smoothfitness.co.uk
29
COMPUTER OPERATION
PROGRAM 8 – HEART RATE CONTROL
If P8 is selected, the TIME LED window shows the factory
setting value of “60:00” and is blinking. Press the SPEED
UP/DOWN buttons to adjust the workout time. Every
adjustable section equals 3 minutes. Press the
STOP/ENTER button to save the setting then the
TARGET HEART RATE displays in the PULSE LED
window and is blinking. The factory TARGET HEART
RATE setting is based on 85% of the maximum user
heart rate. The maximum user heart rate is calculated
using the formula: 220 minus the user age. As an
example, for age 35 the maximum user heart rate
should be 185 and 85% of the maximum user heart
rate will be 157. Press the SPEED UP/DOWN buttons to
adjust the TARGET HEART RATE according to your own
physical condition or your doctor’s instruction then press
the STOP/ENTER buttons to save the setting.
Press the START button to start the three minute WARM UP program. Speed starts from 2.0 mph /3.2 km/h and the
INCLINE LEVEL starts from level 0. Keep your hand on the hand pulse grips all the time during this workout in order to
monitor your pulse correctly. During the program, if the heart rate monitor fails to sense the user’s pulse you will see “P
blinking in the PULSE LED window. If the heart rate monitor senses the pulse properly the PULSE DOT LED blinks and
the correct pulse readout shows on the PULSE LED window. The computer will sense the user’s pulse every 30 seconds.
During the warm up program you can press the STOP/ENTER button to pause or stop the program or press the START
button to re-start the program. Other buttons will not react during this warm up process.
During the warm up program, if the heart rate monitor fails to sense the user’s pulse (the PULSE LED will display a
blinking “P”) the computer will not change the speed. If the heart rate monitor senses the user’s pulse properly but the
actual user’s pulse does not reach 65% of the max. heart rate (( 220-age) x 65%) then the speed will increase by 0.5 mph
/0.8 km/h every 30 seconds. If the actual pulse reaches 65% of the max. heart rate the speed will remain unchanged. If
the actual pulse remains at 65% of the max. heart rate for more than one minute the speed will be maintained until the
warm up program is finished.
If the actual user’s pulse fails to reach 65% of the max. heart rate within the first 3 minutes of the warm up program, the
computer will continue a second 3 minute warm up program. All workout information continues to count up and the timer
counts down from 3:00. During the second 3 minute warm up the computer will change the incline level instead of the
speed. If the heart rate monitor fails to sense the user’s pulse (the PULSE LED will display a blinking “P”) the computer
will not change the incline level. If heart rate monitor senses the user’s pulse properly but the actual user’s pulse does not
reach 65% of the max. heart rate (( 220-age) x 65%) then the incline level will be increased by 1 level every 30 seconds. If
the actual pulse reaches 65% of the max. heart rate the incline level will remain unchanged. If the actual pulse remains at
65% of the max. heart rate for more than one minute the speed will be maintained until the warm up program is finished.
If the actual user’s pulse fails to reach 65% of the max. heart rate within the second 3 minute warm up, the computer will
continue a third 3 minute warm up program. All workout information continues to count up and the timer counts down from
3:00. During the third 3 minute warm up both speed and incline remain unchanged regardless the actual pulse. If the time
counts down to 0 and 65% of the max. heart rate still cannot be achieved then the TIME LED will show “FAIL” and the
program will stop and return to POWER ON status.
After the warm up program is completed, if the actual pulse reaches 65% of the max. heart rate, the computer will enter
the HEART RATE CONTROL program. TIME counts down from the previous setting. Distance and Calories continue to
count up from the warm up program. During the HEART RATE CONTROL program the heart rate monitor will sense the
actual user’s pulse every 30 seconds. If the actual user’s pulse does not reach 85% of the max. heart rate then the incline
level will be increased by 1 level every 30 seconds. If the actual user’s pulse reaches 85% of the max. heart rate then the
treadmill performance will be remain unchanged. If the actual user’s pulse is greater than 85% of the max. heart rate, the
incline level will be reduced by 1 level. Speed will remain unchanged until the incline level increases up to 15% or down to
0%. If the incline level is up to 15% and 85% of the max. heart rate still cannot be reached then the speed will be
increased by 0.5 mph /0.8 km/h every 30 seconds. If the incline level decreases down to 0% and the actual user’s pulse is
still greater than 85% of the max. heart rate then the speed will be decreased by 0.5 mph /0.8 km/h every 30 seconds.