ProForm 495 LS Treadmill User Manual


 
TROUBLESHOOTING
Most treadmill problems can be solved by following the simple steps below. Red the symptom that
applies, and follow the steps listed. If further assistance Is needed, call our toll-free HELPUNE at
1-800-736-6879, Monday through Saturday, 7 a.m. until 7 p.m. Central Time (excluding holidays).
PROBLEM: The power does not turn on
SOLUTION: a. Make sure that the power cordis plugged intoa surge suppressor, and thatthe surge suppressor
isplugged Into a properly grounded outlet (see page 7). Use onlya single-outletsurge suppressor
that meets all ofthe specificationsdescribedon page 7. Important: The treadmill Is not compatible
with GFCI-equipped outlets.
b. After the power cordhas been pluggedin, make sure that the key isfully inserted intothe console.
c. Check the circuit breaker located on the treadmill J=
frame near the power cord. ffthe switch protrudes c
as shown, the cimultbreaker has tdpped. To reset Tdpped
the cimuit breaker, wait for five minutes and then
press the switch back in.
PROBLEM: The power turns off during use
Reset
SOLUTION: a. Check the circuitbreaker located on the treadmill frame near the power cord (see the drawing
above). Ifthe circuit breaker has tripped, wait for five minutes and then press the switch back in.
b. Make sure that the power cord isplugged in. Ifthe power cord is plugged in, unplug it, wait for five
minutes, and then plug it back in.
c. Remove the key from the console. Reinsert the key fully intothe console.
d. If the treadmill still will not ran, please call our toll-free HELPLINE.
PROBLEM: The displays of the console do not function properly
SOLUTION: a. Check the bettedes in the console. Ifthe batteries need to be replaced, see BATTERY
INSTALLATION on page 8. Most problems are the resultof drained batteries.
b. Remove the key from the console and UNPLUG THE
POWER CORD. Remove the Resistance Knob (98)
from the left Upright. RemOve the screws from the
hood, and carefully remove the hood.
Locate the Reed Switch (86) and the Magnet (87) on
the left side of the Pulley (85). Turn the Pulley untilthe
Magnet is aligned with the Reed Switch. Make sure
that the gap between the Magnet and the Reed
Switch is about 1/8". If necessary, loosen the Screw
(82) and move the Reed Switch slightly.Retighten the
Screw. Re-attach the hood, and run the treadmillfor a
few minutes to check for a correctspeed reading.
Reattach the Resistance Knob.
b
Top
View
12