35
E5 – Over-speed Error
Step 1. AUTO CALIBRATION
AUTO-Calibration the as outlined in the System Calibration Procedure in below step.
OVERVIEW
If the actual speed from the speed sensor exceeds the system maximum speed by a limit
(currently 2 MPH) an over-speed error occurs (E5).
Error 5
Enter engineer mode of
“AUTO
CALIBRATION”
Please will start Key
held for 3 seconds to
auto calibration
Measured speed <
14 MPH &
displayed speed >
14 MPH
Speed feedback
issue
Speed control issue
Speed Feedback Issues – See speed feedback issue trouble shooting guide in the
CORRECTIVE ACTION PROCEDURES – Speed Issues section of this document.
Speed Control Issues – See speed control issue trouble shooting guide in the
CORRECTIVE ACTION PROCEDURES – Speed Issues section of this document.
Step 2 :
1.Record when parameter information with error (please refer the 25 page of P1 / P2 /
P3 place) .
2.Remove Power!!! Carefully check all connections.
3.Check interface board (MCB) with the speed sensor ensure contact are correct and fix.
4. If AUTO CALIBRATION can't finish, please take speed sensor to be close to
magnet and AUTO CALIBRATION again.
5.If repeat over speed errors occur remove the treadmill from service.