219
z Port 1 of the commander switch is connecting to the external network, port 2 is connecting to
member switch 1 and port 3 is connecting to member switch 2.
z IP pool: 175.128.0.1, Mask: 255.255.255.0.
¾ Network Diagram
Figure 13-19 Network diagram
¾ Configuration Procedure
z Configure the member switch
Step Operation Description
1 Enable NDP function on the
switch and for port 1
On Cluster→NDP→NDP Config page, enable NDP
function.
2 Enable NTDP function on the
switch and for port 1
On Cluster→NTDP→NTDP Config page, enable
NTDP function.
z Configure the commander switch
Step Operation Description
1 Enable NDP function on the
switch and for port 1, port 2 and
port 3
On Cluster→NDP→NDP Config page, enable NDP
function.
2 Enable NTDP function on the
switch and for port 1, port 2 and
port 3
On Cluster→NTDP→NTDP Config page, enable
NTDP function.
3 Create a cluster and configure
the related parameters
On Cluster→Cluster→Cluster Config page, configure
the role as Commander and enter the related
information.
IP pool: 175.128.0.1
Mask: 255.255.255.0